Operating Instruction
Table Of Contents
4
PT 200
EN
9. Technical Specifications
10.
www.microlife.com
This equipment generates uses and can radiate radio frequency
energy and, if not used in accordance with the instructions, may
cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment on and off, the user is
encouraged to try to correct the interference by increasing the
distance between the product and the affected device,can by
one or more of the following measures
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for
help.
This device complies with FCC radiation exposure limits set
forth for an uncontrolled environment. End users must follow the
specific operating instructions for satisfying RF exposure
compliance. This transmitter must not be co-located or operating
in conjunction with any other antenna or transmitter.
Electromagnetic compatibility: This device fulfills the
stipulations
of the standard IEC 60601-1-2 (EMC).
Technical alterations reserved.
According to the Medical Product User Act a biennial technical
inspection is recommended for professional users. Please
observe the applicable disposal regulations.
The Bluetooth
®
word mark and logos are registered trademarks
owned by Bluetooth SIG, Inc. and any use of such marks by Microlife
Corp. is under license. Other trademarks and trade names are those
of their respective owners.
Portable and mobile RF communications equipment can affect the
device
NOTE: Do not use this device in the presence of electromagnetic
or other interference outside the normal range specified in
IEC60601-1-2.
Type:
Patch Thermometer PT 200
Measurement Operation
: Direct Mode
Measurement range:
32.0 - 43.0 °C / 89.6 - 109.4 °F
Resolution:
0.1 °C / °F
Measurement
accuracy:
Laboratory:
± 0.1 °C / ± 0.2 °F
Memory:
4320 readings if not linked to the smartphone
Operating
conditions:
10 - 40 °C / 50 - 104 °F
15-95 % relative maximum humidity
Storage conditions:
-25 - +60 °C / -13 - +140 °F
15-95 % relative maximum humidity
Automatic
Switch-off:
Automatic switch off after 30 minutes, when
removed from the body.
Communication:
Bluetooth
®
4.0
10 m valid transmission distance in free space
Compatibility:
iOS: iOS 8.0 or newer
Android: Android 5.0 or newer
Battery:
1 x CR2032 battery 3V
Battery lifetime:
approx. 9 days when used 8 hours per day
Dimensions:
Weight:
IP Class:
Reference to
standards:
Expected
service life:
(using a new battery)
53 x 31.5 x 8
mm
11 g (with battery), 8 g (w/o battery)
IP22
ISO80601-2-56, ASTM E1112; IEC 60601-1
;
IEC 60601-1-2 (EMC); IEC 60601-1-11
5 years
Deta
iled user information about our thermo
meters and
blood pressure mon
it
ors as well as ser
vices can be foun
d
at www.microlife.com.
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two condition
s: (1) This device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation. Changes or modifications to the product are not
approved by
Microlife USA and could void the user's authority to
operate the equipment under FCC jurisdiction.
Note:This equipment has been verified to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules.These
limits are designed to provide reasonable protection.against harmful
interference in a residential installation.