Product description
The WatchBP Office consists of two major parts
The device, cuffs and accessories.
The WatchBP Analyzer Software.
With the WatchBP Analyzer Software
1) The device can be programmed for the blood pressure measurement procedure.
2) Measured blood pressure values can be downloaded to the PC.
3) A PDF report and Microsoft Excel spreadsheet for data analysis can be generated.
Contents
1. WatchBP Office AOBP Monitor
(dependent on purchase version*)
2. WatchBP Office Cuff Size M (22- 32cm)
3. WatchBP Office Cuff Size L (32- 42cm)
4. Data Cable
5. Mains adapter
6. Instruction manual
7. Quick start guide
Download the latest WatchBP Analyzer Software from the Microlife website.
https://www.microlife.com/support/software-professional-products
*
Device Version
* The device can be upgraded with special features. There are three different versions of
the device:
Standard version: standard AOBP Monitor
AFIB version: standard AOBP Monitor with Microlife Atrial Fibrillation Detector
CBP version: standard AOBP Monitor with Microlife Atrial Fibrillation Detector and
Central Blood Pressure measurement
Upgrading the device
The Atrial Fibrillation Detector and Central Blood Pressure measurement of the
device can be activated through the WatchBP Analyzer. An activation key is needed
for activation, the activation key is specific for the device as it matches the ID. Please
contact Microlife or the local distributor for additional information.
SYS.
mmHg
DIA.
mmHg
PUL.
/min
START
STOP
Taking ambulatory blood pressure measurements
Product description
Quick start guide
Quick start guide
QSG WatchBP O3_2918
1
Insert batteries
Ensure device
is worn
properly with
tube pointing
upwards
Five seconds reminder
followed by inflation
Connect to PC
Begin 24-hour
ambulatory
measurements
Medication record
(as required)
Measurement schedule
and intervals
Next measurement
countdown
During measurement
do not move arm
Measurement
reminder at one
minute
Return to doctor for
review of data
Take note on
patient diary
after each
measurement
2 3
4
5
6
7
8
9
10
11
12
Awake from with minutes interval06 AM 10 PM 30~
Asleep from with minutes interval10 PM 06 AM 60~
Setting Ambulatory Measurement Schedule
1 min
Reminder
5 sec
Reminder
WatchBP O3
WatchBP Office
AAA
2-3 cm
(3/4 to 1 inch)
MODE
Cuff Socket
Display
MODE
MODE
Start/Stop Button
Start measurement(s) base on the
AUTO or AUS mode in standby
Up Button
To enter SETTING and scroll up/switch
Mode Button
To switch the mode
M Button (Memory)
To enter memory record and
Down function in setting
Battery Compartment
DC 7.5V 1.5A
Power Adapter Socket
USB port
MODE
EN
1
WatchBP
Office
Professional
Blood Pressure
Monitoring Syst em
Instruction Manual
BP 3SK1-3B