- Important Product and Safety Information Follow Instructions for Use. This document provides important product operation and safety information regarding
- This blood pressure monitor IS intended to be used:
- This blood pressure monitor IS NOT intended for use with:
- WARNING – Potentially hazardous situation that if not avoided may result in serious injury or death.
- DO NOT:
- CAUTION – Potentially hazardous situation that if not avoided may result in minor/moderate injury, property damage, and/or damage to the device
- DO NOT: (1)
- STANDARDS
- TYPE
- Expected Life
- Trademark Usage:
- Federal Communications Commission (FCC) Statement
- Premium Automatic Blood Pressure Monitor
- 1. Introduction
- 2. Components of your blood pressure monitor
- 3. How do I get started?
- 4. How do I take a measurement?
- 5. Bluetooth functions and application (App)
- 6. Error messages/troubleshooting 7. How is blood pressure measured?
- 8. Care and maintenance 9. Limited warranty 10. Technical specifications 11. How to contact us
- 1.2. Diabetes validation
- 2. Components of your blood pressure monitor (1)
- 2.2. Wide Range Cuff:
- Anti-Slip Cuff:
- Cuff Sizing:
- Note:
- 3. How do I get started? (1)
- 3.2. Inserting the batteries
- Attention!
- 3.3. Power switch / screen lock
- 3.4. Using the interactive touch screen
- 3.5. Setting the date and time
- 3.6. Select the user
- Before taking a measurement, be certain that the correct user has been selected.
- 3.7. Select measuring mode: standard or Microlife Averaging Mode (MAM)
- 3.8. Microlife Averaging Mode (MAM)
- 3.9. Connecting the cuff and monitor
- 3.10. Using the AC power adapter
- Note: (1)
- 4. How do I take a measurement? Please note: You should always be seated before and during measurement.
- 4.2. Common errors
- 4.3. Using the cuff
- Comment
- 4.4. Taking a measurement
- 4.5. Memory: Reviewing readings
- Viewing the stored values
- Memory full
- Clear all values
- 4.6. Stopping a measurement
- 4.7. Hypertension risk indicator
- 4.8. Irregular heartbeat detector
- Information on frequent appearance of the irregular heartbeat symbol
- 4.9. Battery change indicator
- Note: (2)
- 5. Bluetooth functions and application (App)
- Compatibility:
- Questions?
- 5.1. Bluetooth® icon indicator (on monitor)
- Troubleshooting: Bluetooth® connection:
- 5.2. iOS devices:
- Connecting the devices for the first time:
- Setting up your blood pressure monitor:
- Automatic measurement transfer (iOS):
- Manual measurement transfer (iOS):
- Saving readings stored on your monitor (iOS):
- 5.3 Android OS Phones
- Saving readings to your Android phone:
- 6. Error messages/troubleshooting
- Error No. Possible cause(s)/Solutions
- *If this or any other problem occurs repeatedly, please consult your doctor.
- Malfunction Remedy
- Please note: Blood pressure fluctuates continually so succes- sive measurements will show some variability.
- Please note: Individuals visiting their doctor frequently experi- ence anxiety which can result in a higher reading than at home under resting conditions.
- 7. How is blood pressure measured?
- 7.2. Measurement Guidelines
- Additional information
- 7.3. What can I do to change my blood pressure?
- 1) Eating habits
- 2) Previous illnesses
- 3) Habits
- 4) Physical constitution
- 8. Care and maintenance
- 10. Technical specifications:
- 11. How to contact us
22
4.8.
Irregular heartbeat detector
The appearance of this symbol
indicates that
certain pulse irregularities were detected during the
measurement. In this case, the result may deviate
from your normal basal blood pressure – repeat the
measurement. In most cases, this is no cause for
concern. However, if the symbol appears on a
regular basis (e.g., several times a week with
measurements taken daily), we advise you to tell
your doctor.
Please show your doctor the following explanation:
Information on frequent appearance of the
irregular heartbeat symbol
This instrument is an oscillometric blood pressure
monitor device that also analyzes pulse frequency
during measurement. The instrument is clinically
tested.
If pulse irregularities occur during the measurement,
the irregular heartbeat symbol is displayed with the
measurement.
If the symbol appears frequently or if it suddenly
appears more often than usual, we recommend the
patient seek medical advice. The instrument does
not replace a cardiac examination but serves to
detect pulse irregularities at an early stage.