Installation manual
© Microhard Systems Inc. 59
4.0 Configuration
Image 4-28: Carrier > Keepalive
4.3 Carrier
4.3.3 Carrier > Keepalive
The Keep alive tab allows for the configuration of the keep alive features of the VIP4G. The
VIP4G can either do a ICMP or HTTP keep alive by attempting to reach a specified address at a
regular interval. If the VIP4G cannot reach the intended destination, it will reset the unit in an
attempt to obtain a new connection to the carrier.
Enable or Disable the keep alive functions in the VIP4G.
Keep Alive Status
Values (Selection)
Enable / Disable
Select the type of keep alive used. ICMP uses a “ping” to reach
a select destination.
Type
Values (Selection)
ICMP / HTTP
Specify a IP Address or Domain that is used to test the VIP4G
connection.
Host Name
Values (IP or Domain)
8.8.8.8
The Interval value determines the frequency, or how often, the
VIP4G will send out PING messages to the Host.
Interval
Values (seconds)
300
The Count field is the maximum number of PING errors such as “Host
unreachable” the IPn3G will attempt before the unit will reboot itself to
attempt to correct connection issues. If set to zero (0), the unit will
never reboot itself.
Count
Values (number)
10