Specifications

31
ENGLISH
(Prism wheel error) This message will appear after the fixture resets if the
magnetic indexing circuit malfunctions (sensor failed or magnet missing)
or the stepper motor is defective (or its driver circuit on the main PCB).
The prism-wheel is not located in the default position after the reset.
This error message informs you that the fixture was overheating (occurred if the
ambient temperature is 45° C or more) and that the relay switched off the lamp.
This message will appear on the display until the temperature will be on a suit-
able level, then the display will show the HEAt message meaning the lamp is
too hot (explanation see previous page).
This message appears if the lamp lighting sensor has failed.
Please contact your dealer.
This message will appear if the fixture was recently disconnected from the
power supply.
(PAN-yoke movement error) This message will appear after the fixture resets
if the yoke’s magnetic indexing circuit malfunction (sensor failed or magnet
missing) or the stepper motor is defective (or its driving IC on the main PCB).
The yoke is not located in the default position after the reset.
(TILT-head movement error) This message will appear after the fixture resets
if the head’s magnetic-indexing circuit malfunctions (sensor failed or magnet
missing) or the stepper motor is defective (or its driving IC on the main PCB).
The head is not located in the default position after the reset.
This message will appear if the frequency of the power is not standard 50 or
60 Hz.