Specifications

9. Beampath
19
15 radiation angle
24 radiation angle
18 radiation angle
26 radiation angle
21 radiation angle
15 radiation angle with frost
26 radiation angle with frost
369
3970
92
990
41
440
23 Foot-candles
250 LUX
20 Distance(m)
5,27 Diameter(m)
15
3,95
10
2,63
5
1,30
3
2
1
0
1
2
3
Beam opening (m)
Beam opening (m)
5
4
3
2
1
0
1
2
3
4
5
180
1940
45
485
20
215
11 Foot-candles
120 LUX
20 Distance(m)
8,50 Diameter(m)
15
6,38
10
4,25
5
2,13
18 Foot-candles
190 LUX
33
355
70
755
281
3020
4
3
2
1
0
1
2
3
4
Beam opening (m)
20 Distance(m)
6,34 Diameter(m)
Beam opening (m)
5
4
3
2
1
0
1
2
3
4
5
147
1580
37
395
16
175
9 Foot-candles
100 LUX
4
3
2
1
0
1
2
3
4
Beam opening (m)
5
1,58
10
3,17
15
4,75
241
2600
60
650
27
290
15 Foot-candles
160 LUX
20 Distance(m)
7,41 Diameter(m)
15
5,56
10
3,70
5
1,85
5
2,30
10
4,62
15
6,93
20 Distance(m)
9,20 Diameter(m)
6 Foot-candles
65 LUX
11
114
24
256
95
1024
5
2,49
10
4,99
15
7,48
20 Distance(m)
9,97 Diameter(m)
Beam opening (m)
5
4
3
2
1
0
1
2
3
4
5
223
2400
56
600
25
267
14 Foot-candles
150 LUX
5
1,49
10
2,99
15
4,48
20 Distance(m)
5,98 Diameter(m)
3
2
1
0
1
2
3
Beam opening (m)