3.334 C hime S etting
If you have purchased an optional triac cir-
cuit or internal chime, it can be activated every
time a new number is sent to the Display. The
duration of the triac output given a new number
can be controlled by changing this option. To
change this option, send a page to 9999 with the
message “00_XX” where XX is a number from 00
to 99 representing the number of 0.1 second
intervals that you want the output to be on.
Sending a 00 will cause the triac circuit and the
internal chime to be disabled.
3.335 C lear All Numbers C ommand
There are occasions where you may want to
clear all numbers from all Displays. To clear all
numbers, send a page to Pager 9999 with the
message “99_98.”
3.336 R es et F actory Defaults
To change the Display settings back to fac-
tory defaults send a page to Pager 9999 with the
message “99_99.”
3.337 Us ing the UHF Dis play W ith A
DataP age L ite or DataP age II
The Wireless UHF Display has been de-
signed to work optimally with the MultiPage
software .
However, in rare cases you may want to use the
Display with a Transmitter other than the
MultiPage. If so, you can control the Display's
basic functions by sending pages to the Display’s
address with beep types and messages to control
the function. Beep type “4” enters the number
contained in the message into the Display. Beep
Type “3” removes the number contained in the
message from the Display.