Status Codes
access a local file on a client and you do not have a Workgroup engine 
installed or if you try to access a local file on a server and the Server 
engine is not running.
If you have only a server engine installed and your Pervasive Event 
Log (PVSW.LOG) contains Status Code 3012 warning entries, 
perform the following steps:
³ To Turn Off Local Engine support (for clients and 
workstations only):
1 Start Pervasive PSQL Control Center (see Starting PCC on 
Windows in Pervasive PSQL User's Guide).
2 Expand Local Client. Right-click MicroKernel Router and select 
Properties. Login if prompted.
3 Click Access.
4 In the right hand frame, change the value of Use Local 
MicroKernel Engine to Off.
5 In the right-hand frame, change the value of Use Remote 
MicroKernel Engine to On. Click OK.
6 Restart the engines for the new settings to take effect.
3013: The remote engine is inaccessible to the 
MicroKernel router because the networking component is 
not loaded
Access to the remote engine is not possible because the MicroKernel 
router could not initialize the networking component. Possible 
causes include:
 The client configuration option, AccessUse Remote 
MicroKernel Engine, is incorrectly set to Off. Set it to On to 
access a remote Server engine.
 The required networking component could not be found or is 
not compatible.
3014: The MicroKernel router cannot find an engine
The MicroKernel router could not complete the operation because it 
did not find an engine (local or remote) that could process the 
operation. Possible causes include: