Fixed Frequency:A setting typically used for testing and evaluation
CW/Modulation/Pulse shown in Figure 14 used for engineering evaluation.
CW:To test Output Power Linearity for the desired frequency.
Modulation:To test the Mask for the desired frequency.
Pulse:To test ETSI 302 208 v1.3.1
Time- only used for modulation setting
Figure 14
3.2.5. Gen2 Setting
Figure 15 illustrates how to change or modify the Gen2 profile of the MTI RFID ME and EPC tag.
For more details regarding definitions Gen2 settings, parameters and limits please reference the
Class 1 Generation 2 UHF Air Interface Protocol Standard “Gen 2”
(http://www.epcglobalinc.org/standards/uhfc1g2)
MTI RFID ME HW GUI Default Settings
Link Frequency:160KHz
Session:S0
Coding:Miller 2
Q_Begin:4