Data Sheet
Q Query Settings  0x51  
This command will provide the current tinyLiDAR module settings: 
•  Current Operation Mode: {single step or continuous} 
•  WatchDog Timer: {on/off} 
•  LED Indicator: {on/off/measurement} 
•  Current Preset Configuration: 
{HighSpeed/LongRange/HighAccuracy/tinyLiDAR
 /Custom} 
•  Signal Rate Limit (in MCPS) 
•  Sigma Estimate Limit (in mm) 
•  Timing Budget (in ms) 
•  Pre Range VCSEL Period 
•  Final Range VCSEL Period 
•  tinyLiDAR
 Firmware Version 
•  ST PAL API Version 
•  Offset Cal: {custom or default} 
•  Cal Offset (in mm) 
•  Crosstalk (in MCPS) 
Host -> Sensor 
Send Command 
0x51 {Q}  
Sensor -> Host 
Read Response 
[0] 0x43 for continuous or 0x53 for single step mode 
[1] 0x53 for High Speed, 0x52 for Long Range, 0x41 for High Accuracy, 
0x43 for Custom or 0x54 for tinyLiDAR, else is Unknown preset 
configuration. 
[2][3] for Signal Rate Limit. Scale down by 65536 to get proper value in 
MCPS. Note that we are limited to a readout max value of 0.99MCPS due 
to the 16bit read but the serial log terminal output is not limited. 
[4] for Sigma Estimate Limit. In mm.  
[5][6] for Timing Budget in ms.  
[7] for 0x0e or 0x12 for 14/10 or 18/14 VCSEL period settings. 
[8][9][10] for the tinyLiDAR
 firmware version number. 
[11][12][13] for the ST PAL API version number. 
tinyLiDAR Reference Manual rev1.26  22 