Data Sheet
W Write custom VL53L0X config 0x57…   
Write new VL53L0X configuration parameters. 
Parameters are written in the following order: Signal Limit, Sigma Limit, 
Time Budget, VCSEL Period selection. This command requires a sequence 
of steps which are best understood by following the code from the tinyLiDAR
Terminal GUI sketch shown in Appendix A.  
Host -> Sensor 
Send Command 
0x57 {W},  
Signal Rate Limit in MCPS written as 100x the required value, {required 
range is  0.00 to 65.00MCPS so have to write 0 to 6500 here} 
Sigma Limit in mm, 
Timing Budget in milliseconds (ms), {range is 20ms to 2000ms } 
VCSEL Period selection, {choose either 18 or 14 here to signify which pair of 
values you want to choose} 
18 means: 
“Pre-range VCSEL Period = 
18
 and Final-range VCSEL Period = 14” 
14 means:
“Pre-range VCSEL Period = 
14
 and Final-range VCSEL Period = 10” 
Example:  
Set tinyLiDAR at the default address of 0x10 to the “High Accuracy” 
configuration parameters:  
Signal Limit = 0.25 MCPS, so write 100x 0.25 = 25 which is 0x0019 
Sigma Limit = 18 mm, so write 0x12 
Time Budget = 200 ms, so write 0x00c8 
Pre-range VCSEL Period = 14, Final-range VCSEL Period = 10, so write 0x0e 
<10:w> 57 00 19 12 00 c8 0e  
Note that on the GUI Terminal this would be entered as: 
w 25 18 200 14 
tinyLiDAR Reference Manual rev1.26  18 