Data Sheet

Q Query Settings 0x51
This command will provide the current tinyLiDAR module settings:
Current Operation Mode: {single step or continuous}
WatchDog Timer: {on/off}
LED Indicator: {on/off/measurement}
Current Preset Configuration:
{HighSpeed/LongRange/HighAccuracy/tinyLiDAR
/Custom}
Signal Rate Limit (in MCPS)
Sigma Estimate Limit (in mm)
Timing Budget (in ms)
Pre Range VCSEL Period
Final Range VCSEL Period
tinyLiDAR
Firmware Version
ST PAL API Version
Offset Cal: {custom or default}
Cal Offset (in mm)
Crosstalk (in MCPS)
Host -> Sensor
Send Command
0x51 {Q}
Sensor -> Host
Read Response
[0] 0x43 for continuous or 0x53 for single step mode
[1] 0x53 for High Speed, 0x52 for Long Range, 0x41 for High Accuracy,
0x43 for Custom or 0x54 for tinyLiDAR, else is Unknown preset
configuration.
[2][3] for Signal Rate Limit. Scale down by 65536 to get proper value in
MCPS. Note that we are limited to a readout max value of 0.99MCPS due
to the 16bit read but the serial log terminal output is not limited.
[4] for Sigma Estimate Limit. In mm.
[5][6] for Timing Budget in ms.
[7] for 0x0e or 0x12 for 14/10 or 18/14 VCSEL period settings.
[8][9][10] for the tinyLiDAR
firmware version number.
[11][12][13] for the ST PAL API version number.
tinyLiDAR Reference Manual rev1.26 22