Data Sheet

Y LED mode save with reboot
0x59
Same as the X command but also writes the LED indicator mode to non-
volatile storage. Note that this command will cause tinyLiDAR
to write this
mode to non-volatile memory and reboot. Therefore please allow some time
for it to reboot.
Host -> Sensor
Send Command
0x59 {Y}
Example:
Save LED mode and reboot now.
<10:w> 59
RESET Reset to factory defaults
0x00 0x06
Reset tinyLiDAR to the default board address of 0x10 and clear user settings.
Please note, this command uses a special broadcast address of 0x00 to talk
to all tinyLiDAR
modules connected to the I2C bus. After writing the default
address to the non-volatile memory and resetting configuration settings to
factory defaults, the module will reboot. Therefore please allow some time
for it to reboot. Note that as of FW:1.4.0, you can also ground the Clear Pin
to get this function.
Host -> Sensor
Send Command
0x00, 0x06
Example:
Reset tinyLiDAR to factory defaults.
<10:w> 00 06
tinyLiDAR Reference Manual rev1.26 14