Specifications

46
• If the settings are changed, they become effective when the BA-T500 is reset other power is turned
on again.
• The setting values can be checked by executing the self-test.
GS ( E pL pH m a (m = 4) <Function 4>
[Format]
ASCII GS ( E pL pH m a
Hex 1D 28 45 p
L pH 04 a
Decimal 29 40 69 p
L pH 4 a
[Range] ( pL + pH x 256) = 2 ( pL = 2, pH = 0)
m = 4
1
a 8
[Function] Sends the setting values of the memory switch specified with a
The contents of the transmit data are as follows:
Transmit data Hex Decimal Number of data
Header
37H 55 1 byte
Flag
21H 33 1 byte
Data
30H, 31H 48, 49 8 bytes
NUL
00H 0 1 byte
Contents of data shown in above:
The on/off setting of the memory switch is defined as [Off: Hex=30H/Decimal=48] or [On: Hex=31H
/ Decimal=49]. Each 1 byte for 8 memory switches are transmitted from bit 8 to bit 1.
Example: Transmitted data: “10110001”
(31H, 30H, 31H, 31H, 30H, 30H, 30H, 31H)
Switch No. 8 7 6 5 4 3 2 1
Status On Off On On Off Off Off On
• If an unsupported memory switch number is selected, this command is ignored.
• If this command is ignored, the printer doesn’t send any data.
GS * x y d1...d(x × y × 8)
[Name]
[Format]
[Range]
[Description]
Define downloaded bit image
ASCII GS * x y d1...d(x × y × 8)
Hex 1D 2A x y d1...d(x × y × 8)
Decimal 29 42 x y d1...d(x × y × 8)
1 x 255, 1 y 255
x × y 2048
0 d 255
Defines a downloaded bit image using the number of bytes specified by x and y
x specifies the number of dots in the horizontal direction.