Operator`s manual
Appendix D Quick Reference Command Summary
))))))))))))))))))))))))))))))))))))))))))))
))))))))))))))))))))))))))))))))))))))))))))
470 Operators Manual
107
XX 61 Mark Text Starting Position: ^A designates which text field to start entering
new data. Section 5.3.8.
62 Pre-padded Text: This command is sent after text that is to appear at the
beginning of each field is sent.
63 Text Mode Control: Section 5.3.8.
0 Disable 1 & 2.
1 Enable auto-print mode
2 Clear all previous text upon receiving new data.
3 Enable 1 & 2.
XX 64 Auto Print String Count: ^A tells the printer how many text strings to accept
before printing. Section 5.3.
XX 65 Load Text Segment Number: Valid range is 1 to 32.
X 66 Clear Single Non-Volatile Saved Format File: This command will clear a single
non-volatile saved format and open the slot for a new file. Section 5.3.8.
67 24 Hour Date Format:
0 24 hour format.
1 12 hour format.
70 Clock Chip Initialization: Non-Destructive initialization of battery backed clock
functions. This command should be sent whenever the clock chip is replaced or
erratic clock operation exist.
X 71 Clear Single Non-Volatile Graphic: This command will clear a single Non-
Volatile graphic file and open the slot for a new file.
XX 73 Load copies count: Tells the printer to print a group of labels. Will not
increment serial numbers (use ^D75).
1 74 Infinity Print: Prints a batch of labels like ^D75 but will continue to print until
the machine is turned off.
XX 75 Load Label Count: Tells the printer to print a batch of labels using the serial
number function if enabled.
XX 76 Load Delay Time Between Labels: Preceded by ^A which contains the wait in
1/10ths of a second. Maximum value is 650.