M SERIES
INSTRUCTION MANUAL
INTRODUCTION
1
1.8 MAIN FEATURES OF POWER CONTROL CARDS
Power control cards are submitted to the EC 73/23
Directive known as “Low Voltage” and conform to EN
61010-1 standards.
Depending on cabinet configuration, two types of
power control cards that can be integrated in M
Series cabinets: 16A power control card (3600W) and
5A power control card (1000W).

Length: 3.74” (95 mm)
Width: 2.16” (55 mm)
Weight of 16A power control card: < 0.1 lbs (64 g)
1.9 PLANT POWER SUPPLY
230V single phase.
1.10 TOLERANCES ON POWER SUPPLY
207V to 253V
1.11 MAxIMUM CONSUMED POWER
For 16A power control card: 3600W.
For 5A power control card: 1000W.
1.12 FREqUENCY
50Hz to 60Hz.
1.13 MAIN FEATURES ON THERMOCOUPLE
INPUT CARDS
Cards for thermocouples are submitted to the EC
73/23 Directive known as “Low Voltage” and conform
to EN 61010-1 standards.

Length: 80 mm
Width: 42 mm
0,022 Kgs
1.14 POWER SUPPLY
12V DC.
1.15 CONNECTION TO PLANT POWER
Controllers should be grounded to a suitable ground.
It is required to conform to wiring diagrams for
preventing any serious damage caused to the
cabinet.
When supplied
in 400V, neutral wiring is required otherwise
safety function is impossible. The safety circuit on
synchronization card will trip the circuit breaker.
1.16 INSTALLATION
Installation in dry industrial conditions.
Window for service temperature: from 14°F to 140°F.
Take care when unpacking / moving the controller
1.17 DEFINITION OF CEM APPLICABLE
STANDARDS
Standard on emission in industrial environment:
EN 50081-2
Standard on immunity in industrial environment:
EN 50082-2