Instruction manual

©INCOE® CORPORATION 8/2010
Pg. 4
www.incoe.com
1
M SERIES
INSTRUCTION MANUAL
INTRODUCTION
1.2 CABINET CONFIGURATIONS
Cabinets are submitted to EC 73/23 Directive known
as “Low Voltage” and conform to EN 61010-1
Standards.
Each cabinet is equipped with a supply cable sized
according to the maximum admissible current.
IMPORTANT NOTICE: If neutral is involved (Mainly
for Europe market), during softstart the current value
on neutral may exceed current value on one of the
three phases.
This overcurrent is controlled by the main circuit
breaker on backside of the cabinet.
The power consumed depends on the power of the
heating elements and on the number of control loops.
Dimensions of 4U cabinet:
Height: 8.50” (216mm)
Width: 21 “ (534mm)
Depth: 18.50” (470mm)
Weight of 4U cabinet:
Empty: 16.9 Lbs (7,7 Kg) or with 16 power control
cards 16A: 52.6 Lbs (25,3 Kg)
Dimensions of 9U cabinet:
Height: 17.16” (436mm)
Width: 21 “ (534mm)
Depth: 18.50” (470mm)
Weight of 9U cabinet:
Empty: 28.4 Lbs (12,9 Kg) or with 32 power control
cards 16A: 105.8 Lbs (48,1 Kg)
A sticker is affixed on backside of cabinet showing:
to identify when the cabinet was
built (eg: 01220B stands for 20th December 2000, B
is an index).
cabinet designation (M4U-16.00: 16 zones 16A).
all cabinets are designed for use either
in 50 or 60 Hz.
 in three phases either in 230V or 400V with
Neutral.
depends on diameter
and length of supply cable.
Other stickers show:
- Wiring diagram of thermocouples.
- Wiring diagram of heating elements.
It is required to conform with wiring information.