OPERATION

Turn to on the line ”Activate MoldScan option” with
the left and right arrows, then validate; this is done
from the System page (CFG1) or in the MODIF menu.
: when this feature is
selected, a diagnostic on the zone(s) in automatic
mode and currently under temperature low or high
alarms is performed. A new Scan is carried out on
these zones until the alarm disappears. When not
selected, the Analysis can be started manually with
the Scan menu.
A fourth main page is displayed when the line
“Active MoldScan function “ is ON:
A: shows the type of control zone (16A cards or
5A cards). Depends on the configuration of the
cabinet.
B: to manually start the Scan of the tool.
C: to display all parameters for the mold Analysis.

- Amps for each control zone.
- Power (in Watts) for each control zone.
- Resistance (in ohms) of each heating element.
- Response time (in °/min) for each control zone
D: to show all alarms recorded in logbook.
E: to display actual temperature for each control
zone and their setpoint in a graphical form.
B C D E F
A