Operator`s manual

Appendix B Quick Reference Command Summary
466 Operators Manual 85
A ^D COMMAND
26 Change SW6: Change software switch bank #6.
12345678
^ABxxxxxxxx
*******. 1=Disable ON/OFF LINE Button, 0=Enable
******.) Not Used
*****.)) Not Used
****.))) 1=Stacker Enable, 0=Disable
***.)))) 1=Enable Cutter at Power-up, 0=Disable
**.))))) 0=Cutter Type A, 1=Cutter Type B
*.)))))) 1=Use > and # for C128 commands, 0=Use #
.))))))) 1=Enable Slew Speed, 0=Disable
29 Printer Statistics:
0 Print statistics to serial port
1 Print statistics on a label
2 Clear the printed labels variable in the statistics
3 Clear the printed inches variable in the statistics
30 Change Clock: Use the sequence below to set the time and date of the
optional real-time clock:
^D30 (return)
HH:MM:SS (return)
DD/MM/YY/W (return)
31 Show Clock: This command will send the date and time to the serial port.
32 Reset Machine: Restores printer to power-up settings.
33 Display Model and Revision Number.
XX 35 Contrast Window Adjust: This is the temporary contrast adjustment. The ^AXX
is between 10 and 200%
XX 36 Adjust Contrast Base: Non-Volatile command. The ^AXX is between 10 and
200%. Section 5.3.
XX 37 Show Voltages: This command will send the values of the internal printer
voltages.
39 Auto-Size Label: Section 5.3.3.
0 Clears the use of auto-size values set by ^A1^D39.
1 Uses the values obtained for the variables instead of what the user supplies in
the header of the format file. Note: The ^D91 value is stored in non-volatile
memory.
2 Automatically sizes the label and displays on the screen the values for the size
variables.
3 Same as ^A2^D39, but prints the values on a label, instead of on the screen.
10 Move media to “Top of Form” position