Operator`s manual

43
^A ^D COMMAND
23 Change SW3: Software dip switch #3. Below is the ^AB sequence:
12345678
^ABxxxxxxxx
*******.)
Not Used
******.)
Not Used
*****.))
1=Ribbon Break Sensor Disable, 0=Enable
****.)))
1=Pulse Tone On Piezo, 0=Continuous
***.))))
1=Head Up Error Disable, 0=Enable
**.)))))
1=Response After Print Enable, 0=Disable
*.))))))
Not Used
.)))))))
1=Piezo Sound Disable, 0=Enable
Position:
1 Piezo Sound: If set to 1, the piezo is disabled.
2 Not Used
3 Response After Print: If enabled, an enquiry response will be sent back through
the communications port after every print.
4 Head Up Error: If set to 1, head up error checking is disabled.
5 Pulse Tone On Piezo: If set to 1, the piezo is disabled.
6 Ribbon Break Sensor: If disabled, no error will occur if ribbon is out.
7 Not Used
8 Not Used