Operator`s manual
Quick Reference Command Summary Appendix D
412 Operators Manual
90
^A ^D COMMAND
24 Change SW4: Change software dip switch #4. Below is the ^AB sequence.
12345678
^ABxxxxxxxx
*******.)))))),
******.)))))),*
*****.)))))),**
****.)))))),***
**** 0000 = Not decoded (default)
**** 0001 = Danish
**** 0010 = 860
**** 0011 = Spanish
**** 0100 = 850
**** 0101 = German
**** 0110 = 865
**** 0111 = Swiss
**** 1000 = 852
**** 1001 = French
**** 1010 = 863
**** 1011 = Swedish
**** 1100 = 437
**** 1101 = Italian
**** 1110 = British
**** 1111 = US English
****
***.)))))Q 1=Auto-size on Power-up, 0=Disable
**.))))))Q 1=Blow-hole Sensing Enable, 0=Disable
*.)))))))Q 1=External Print Request Enable,
0=Disable
.))))))))Q 1=Enable Slashed Zeros, 0=Disable
29 Printer Statistics:
0 Print statistics to serial port
1 Print statistics on a label
2 Clear the printed labels variable in the statistics
3 Clear the printed inches variable in the statistics
30 Change Clock: Use the sequence below to set the time and date of the
optional real-time clock:
^D30 (return)
HH:MM:SS (return)
DD/MM/YY/W (return)
31 Show Clock: This command will send the date and time to the serial port.
32 Reset Machine: Restores printer to power-up settings. Also used to set the
non- volatile fields in memory. Section 5.3.
33 Display Model and Revision Number.