^A
^D COMMAND
21 Change SW1: Software dip switch #1. The dip switches are the only commands
that do not use the ^A parameters. Instead, they use a ^AB sequence followed
by an 8 digit 0 or 1 code.
For example: ^AB10100001^D21 will configure serial port #1 for text
equivalent enquiry response, accept control codes, disable echo, and enable
XON/XOFF flow control.
12345678
^ABxxxxxxxx
*******.Q 1=XON/XOFF Enable, 0=Disable
******.)Q 1=8 Data Bits, 0=7 Data Bits
*****.))Q 1=Echo Enable, 0=Disable
****.)))Q 1=No Parity, 0=Enable Parity
***.))))Q 1=Odd Parity, 0=Even Parity
**.)))))Q 1=Ignore Control Codes, 0=Accept
*.)))))))))),
.)))))))))),* Enquiry Response
00 = Control Codes
10 = Text Equivalent
11 = ^ Equivalent
Position:
1,2 Enquiry Response: This determines what the printer will send back in response
to an enquiry. See chapter 5.
3 Control Codes: This switch setting will allow or disallow printer response to
control codes (below 20h).
4 Not Used
5 Not Used
6 Echo: If this feature is enabled, the printer will echo all received characters to
the serial port.
7 Not Used
8 XON/XOFF: Enable or disable XON/XOFF software handshaking. CTS/RTS
hardware handshaking is always enabled.