Operator`s manual

Quick Reference Command Summary Appendix D
412 Operators Manual
92
XX 54 Send Saved Format File to Serial Port: ^A selection which one (1-128).
Section 5.3.6.
XX 55 Select Default Label Layout: Select from the ROM power-up layouts. ^AXX
ranges from 1 to 8.
56 Select User Defined Layout: Signals the end of the label field definition.
57 Enter Label Format Mode: This tells the printer that information for a label is
following.
XX 58 Process Saved Format: ^A selects which one (1-128). Section 5.3.6.
XX 59 Save Format File: ^A selects which one (1-128). Section 5.3.6.
60 Clears command 61
XX 61 Mark Text Starting Position: ^A designates which text field to start entering
new data. Section 5.3.8.
62 Pre-padded Text: This command is sent after text that is to appear at the
beginning of each field is sent.
63 Text Mode Control: Section 5.3.8.
0 Disable 1 & 2.
1 Enable auto-print mode
2 Clear all previous text upon receiving new data.
3 Enable 1 & 2.
XX 64 Auto Print String Count: ^A tells the printer how many text strings to accept
before printing. Section 5.3.
XX 66 Clear Single Stored Label Format: ^A select which slot to clear (1-128).
70 Clear commands 73-76.
71 Load Maxicode Bar Code Data:
XX 73 Load copies count: Tells the printer to print a group of labels. Will not
increment serial numbers (use ^D75).
1 74 Infinity Print: Prints a batch of labels like ^D75 but will continue to print until the
machine is turned off.
XX 75 Load Label Count: Tells the printer to print a batch of labels using the serial
number function if enabled.
XX 76 Load Delay Time Between Labels: Preceded by ^A which contains the wait in
1/10ths of a second. Maximum value is 650.
77 Load PDF-417 Bar Code Data: