Operator`s manual

Designing Labels Using LDS Chapter 4
4-16 428TC Operator’s Manual - 880041-0141
Standard Downloadable Font Set
CGN
VALUE
POINT
SIZE
FONT TYPE
52 12 OCR-B Normal 0 degree
53 12 OCR-B Normal 90 degree
54 8 OCR-B Normal 0 degree
55 8 OCR-B Normal 90 degree
Table 4-5 CGN - Standard Downloadable Font Set
4.6.6.3 Embedded Bar Codes
Certain bar codes can be printed using various ratios and character spacing options. The
following table illustrates these options. See Chapter 8 for more detailed information on
designing label formats using bar code symbols. Some bar codes do not require a CGN
value and should be omitted by entering the comma delimiter.
For Example: If a TCI of 40 is selected the CGN will be omitted by entering nothing for the
CGN and surrounding the parameter with the comma delimiter.
1,200,200,10,40,,0,0,100,1
Bar Code Symbologies
SYMBOL
CGN
VALUE
RATIO HEIGHT SPACING FO **
Code 39
2
3
5
8
2:1
3:1
5:2
8:3
1
1
1
1
2
2
2
3
0123
0123
0123
0123
I 2 of 5
2
3
5
7
8
2:1
3:1
5:2
7:3
8:3
1
1
1
1
1
-
-
-
-
-
0123
0123
0123
0123
0123
UPC / EAN * - 40 % 1 - 0123
UPC Readable * - 40 % 1 - 0123
Code 128 & UCC / EAN 128 * - 40 % 1 - 0123
Codabar
2
3
5
2:1
3:1
5:2
1
1
1
-
-
-
0123
0123
0123
Code 93 - 2:1 1 - 0123
AS-10 - 2:1 1 - 0123
Maxicode (CGN = Mode)
2
3
4
5
6
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0123
0123
0123
0123
0123
MSI (Modified Plessey) - 1:1 1 - 0123
Table4-6 CGNBar Code Symbologies