Operator`s manual
Appendix D Quick Reference Command Summary
400 Operators Manual
85
24 Change SW4: Software dip switch #4. An EEPROM command.
Below is the ^AB sequence.
12345678
^ABxxxxxxxx
*******.))
Always 0
******.)))
Always 0
*****.))))
Always 0
****.)))))
Always 0
***.))))))
1=Auto-size on Power-up, 0=Disable
**.)))))))
1=Blow-hole Sensing Enable, 0=Disable
*.))))))))
Always 0
.)))))))))
Always 0
29 Printer Statistics:
0 Print statistics to serial port
1 Print statistics on a label
2 Clear the printed labels variable in the statistics
3 Clear the printed inches variable in the statistics
30 Change Clock: Use the sequence below to set the time and date of the
optional real-time clock:
^D30 (return)
HH:MM:SS (return)
DD/MM/YY/W (return)
31 Show Clock: This command will send the date and time to the serial port.
32 Reset Machine: Restores printer to power-up settings. Also used to set the
EEPROM fields in memory. Section 5.3.
33 Display Model and Revision Number.
35 Contrast Window Adjust:
1 60% of Base
2 70% of Base
3 80% of Base
4 90% of Base
5 Base (default)
6 110% of Base
7 120% of Base
8 130% of Base
9 140% of Base
XX 36 Adjust Contrast Base: An EEPROM command. The ^AXX is between 10 and
200%. Section 5.3.