Operator`s manual
Chapter 5 Printer Commands
324M/424M Operator’s Manual - 880026-0144 5-19
Autoheader User Mode
The Autoheader User Mode operates in a similar fashion to the Table Mode,
but uses a table that the user creates. The user can have up to three stock
ranges within the table (3, 6, or 9 values).
To enter stock ranges use the ^D170 command as follows.
The 1st range is entered like this:
^A1^D170[CR]Range1LowThreshold[CR]
^A2^D170[CR]Range1Target[CR]
^A3^D170[CR]Range1UpperThreshold[CR]
The 2nd range is entered like this:
^A4^D170[CR]Range2LowThreshold[CR]
^A5^D170[CR]Range2Target[CR]
^A6^D170[CR]Range2UpperThreshold[CR]
The 3rd range is entered like this:
^A7^D170[CR]Range3LowThreshold[CR]
^A8^D170[CR]Range3Target[CR]
^A9^D170[CR]Range3UpperThreshold[CR]]
Value1 is the lower boundary, value3 is the upper boundary, and value2 is the
blsy value for this range. Up to 9 values can be entered for a total of 3 ranges.
All values are non volatile and are stored with the other non volatile
parameters. Like the table, if the measured blsy doesn’t fall into any of the
ranges the value won’t change and will be used as is.
To see all of the table and user values enter
^A0^D170 [CR]
Using one of these smart autosize modes gives the user single dot accuracy in
using Boca autosize to find blsy.
6 Reserved
203 dpi
low norm hi
355 406 457
458 508 558
559 609 634
635 660 685
686 711 761
762 812 863
864 914 964
965 1015 1066
1067 1117 1129
1130 1142 1180
1181 1218 1269
1270 1320 1370
1371 1421 1827
1828 2233 2300
300 dpi
low norm hi
525 600 675
676 750 825
826 900 938
939 975 1013
1014 1050 1125
1126 1200 1275
1276 1350 1425
1426 1500 1575
1576 1650 1669
1670 1688 1744
1745 1800 1875
1876 1950 2025
2026 2100 2700
2701 3300 3400