Operator`s manual

13-8 324M/424M Operator’s Manual - 880026-0144
1111 = US English (7 bit)
^AB ^D COMMAND
25 Software Bank Switch #5: A non-volatile command used to set the various
functions identified below.
^AB12345678
Position:
1 1 = Enable Single Button Error Clear; 0 = Disable
2 1 = Display >BUTTON PRESSED<; 0 = Disable
3 1 = TOF sensor is transmissive; 0 = TOF is reflective
4 1 = Enable TOF on Power-up; 0 = Disable
5 1 = Button is TOF; 0 = Button is Defined by SW#2 bit4
6 1 = Enable AutoLoad; 0 = Disable
7 1 = AutoLoad+TOF; 0 = Autoload+FF
8 1 = Enable Status Byte Mode; 0 = Disable
26 Software Bank Switch #6: A non-volatile command used to set the various
functions identified below.
^AB12345678
Position:
1 1 = Enable >TRAY FULL< response; 0 = Enable Test Pattern
2 1 = Enable STL Emulation; 0 = Disable
3 1 = Enable Pre-Stock Out Feature; 0 = Disable
4 1 = Enable >STOCK NOT LOADED< response; 0 = Disable
5 1 = Enable 48-466 Compatibility mode; 0 = Disable
6 1 = General Purpose I/O Enable; 0 = Custom I/O Enable
7 1 = Enable Takeup Control; 0 = Enable Cutter Control
8 1 = Enable Nonstick TOF Mode; 0 = Disable
27 Software Bank Switch #7: A non-volatile command used to set the various
functions identified below.
^AB12345678
Position:
123 Select STL Stock Class:
100 Standard Ticket
010 Cinema Ticket
001 Wristbands
456 Select STL Stock Width (Inches):
000 1.00
100 1.328
010 2.00
110 2.125
001 2.50
101 2.75
011 3.25
111 4.00
7 1 = Disable System Parameter Saving; 0 = Enable