Operator`s manual

324M/424M Operator’s Manual - 880026-0144 13-7
678 Power-up / ROM Format Selection:
000 = No Power-up Format
001 = ROM or Saved Format File 1
010 = ROM or Saved Format File 2
011 = ROM or Saved Format File 3
100 = ROM or Saved Format File 4
101 = ROM or Saved Format File 5
110 = ROM or Saved Format File 6
111 = ROM or Saved Format File 7
23 Software Bank Switch #3: A non-volatile command used to set the various
functions identified below.
^AB12345678
Position:
1 1 = Disable Extended ASCII; 0 = Enable
2 1 = Active LOW for >INPUT1<; 0 = Active HIGH
3 1 = Send Enquiry Response after Print; 0 = Disable
4 1 = Active LOW for >INPUT2<; 0 = Active HIGH
5 1 = Disable use of | for control; 0 = Enable
6 1 = Disable use of ^ for control; 0 = Enable
7 1 = Enable Binary Compression; 0 = Disable
8 1 = Enable Detect Blackline on Power-up; 0 = Disable
^AB ^D COMMAND
24 Software Bank Switch #4: A non-volatile command used to set the various
functions identified below.
^AB12345678
Position:
1 1 = Enable Slashed Zeros; 0 = Disable
2 1 = External Print Request; 0 = Disable
3 1 = Disable Stock Out Sensing; 0 = Enable
4 1 = Enable Auto-size on Power-up; 0 = Disable
5678 Code Pages:
0000 = Not decoded (8 bit)
0001 = Danish (7 bit)
0010 = 860 (8 bit)
0011 = Spanish (7 bit)
0100 = 850 (8 bit)
0101 = German (7 bit)
0110 = 865 (8 bit)
0111 = Swiss (7 bit)
1000 = 852 (8 bit)
1001 = French (7 bit )
1010 = 863 (8 bit)
1011 = Swedish (7 bit)
1100 = 437 (8 bit)
1101 = Italian (7 bit)
1110 = British (7 bit)