Datasheet
2015 Microchip Technology Inc. Preliminary DS60001320B-page 441
PIC32MZ Embedded Connectivity with Floating Point Unit (EF) Family
bit 3 STRGLVL: Scan Trigger High Level/Positive Edge Sensitivity bit
1 = Scan trigger is high level sensitive. Once STRIG mode is selected (TRGSRCx<4:0> in the ADCTRGx
register), the scan trigger will continue for all selected analog inputs, until the STRIG option is removed.
0 = Scan trigger is positive edge sensitive. Once STRIG mode is selected (TRGSRCx<4:0> in the
ADCTRGx register), only a single scan trigger will be generated, which will complete the scan of all
selected analog inputs.
bit 2-0 Unimplemented: Read as ‘0’