Datasheet

Table Of Contents
PIC24FV32KA304 FAMILY
DS30009995E-page 284 2011-2017 Microchip Technology Inc.
FIGURE 29-12: I
2
C BUS START/STOP BITS TIMING CHARACTERISTICS (MASTER MODE)
TABLE 29-31: I
2
C BUS START/STOP BIT TIMING REQUIREMENTS (MASTER MODE)
AC CHARACTERISTICS
Standard Operating Conditions: 2.0V to 3.6V
(unless otherwise stated)
Operating temperature -40°C T
A
+85°C for Industrial)
-40°C T
A
+125°C for Extended
Param
No.
Symbol Characteristic Min
(1)
Max Units Conditions
IM30 T
SU
:
STA
Start Condition
Setup Time
100 kHz mode T
CY
/2 (BRG + 1) s Only relevant for
Repeated Start
condition
400 kHz mode T
CY
/2 (BRG + 1) s
1 MHz mode
(2)
T
CY
/2 (BRG + 1) s
IM31 T
HD
:
STA
Start Condition
Hold Time
100 kHz mode T
CY
/2 (BRG + 1) s After this period, the
first clock pulse is
generated
400 kHz mode T
CY
/2 (BRG + 1) s
1 MHz mode
(2)
T
CY
/2 (BRG + 1) s
IM33 T
SU
:
STO
Stop Condition
Setup Time
100 kHz mode T
CY
/2 (BRG + 1) s
400 kHz mode T
CY
/2 (BRG + 1) s
1 MHz mode
(2)
T
CY
/2 (BRG + 1) s
IM34 T
HD
:
STO
Stop Condition 100 kHz mode T
CY
/2 (BRG + 1) ns
Hold Time 400 kHz mode T
CY
/2 (BRG + 1) ns
1 MHz mode
(2)
T
CY
/2 (BRG + 1) ns
Note 1:
BRG is the value of the I
2
C Baud Rate Generator. Refer to
Section 17.3 “Setting Baud Rate When
Operating as a Bus Master”
for details.
2:
Maximum pin capacitance = 10 pF for all I
2
C pins (for 1 MHz mode only).
SCLx
SDAx
Start
Condition
Stop
Condition
Note:
Refer to Figure 29-3 for load conditions.
IM31
IM30
IM34
IM33