DS39631E-page 280 © 2008 Microchip Technology Inc.
BTFSC Bit Test File, Skip if Clear
Syntax: BTFSC f, b {,a}
Operands: 0 ≤ f ≤ 255
0 ≤ b ≤ 7
a ∈ [0,1]
Operation: skip if (f<b>) = 0
Status Affected: None
Encoding: 1011 bbba ffff ffff
Description: If bit ‘b’ in register ‘f’ is ‘0’, then the next 
instruction is skipped. If bit ‘b’ is ‘0’, then 
the next instruction fetched during the 
current instruction execution is discarded 
and a 
NOP is executed instead, making 
this a two-cycle instruction. 
If ‘a’ is ‘0’, the Access Bank is selected. If 
‘a’ is ‘1’, the BSR is used to select the 
GPR bank (default). 
If ‘a’ is ‘0’ and the extended instruction 
set is enabled, this instruction operates in 
Indexed Literal Offset Addressing 
mode whenever f ≤ 95 (5Fh). 
See Section 24.2.3 “Byte-Oriented and 
Bit-Oriented Instructions in Indexed 
Literal Offset Mode” for details.
Words: 1
Cycles: 1(2)
Note: 3 cycles if skip and followed
by a 2-word instruction.
Q Cycle Activity:
Q1 Q2 Q3 Q4
Decode Read
register ‘f’
Process 
Data
No 
operation
If skip:
Q1 Q2 Q3 Q4
No 
operation
No 
operation
No 
operation
No 
operation
If skip and followed by 2-word instruction:
Q1 Q2 Q3 Q4
No 
operation
No 
operation
No 
operation
No 
operation
No 
operation
No 
operation
No 
operation
No 
operation
Example:
HERE
FALSE
TRUE
BTFSC
:
:
FLAG, 1, 0
Before Instruction
PC = address (HERE)
After Instruction
If FLAG<1> =  0;
PC = address (TRUE)
If FLAG<1> =  1;
PC = address (FALSE)
BTFSS Bit Test File, Skip if Set
Syntax: BTFSS f, b {,a}
Operands: 0 ≤ f ≤ 255
0 ≤ b < 7
a ∈ [0,1]
Operation: skip if (f<b>) = 1
Status Affected: None
Encoding: 1010 bbba ffff ffff
Description: If bit ‘b’ in register ‘f’ is ‘1’, then the next 
instruction is skipped. If bit ‘b’ is ‘1’, then 
the next instruction fetched during the 
current instruction execution is discarded 
and a 
NOP is executed instead, making 
this a two-cycle instruction. 
If ‘a’ is ‘0’, the Access Bank is selected. If 
‘a’ is ‘1’, the BSR is used to select the 
GPR bank (default). 
If ‘a’ is ‘0’ and the extended instruction 
set is enabled, this instruction operates 
in Indexed Literal Offset Addressing 
mode whenever f ≤ 95 (5Fh). 
See Section 24.2.3 “Byte-Oriented and 
Bit-Oriented Instructions in Indexed 
Literal Offset Mode” for details.
Words: 1
Cycles: 1(2)
Note: 3 cycles if skip and followed
by a 2-word instruction.
Q Cycle Activity:
Q1 Q2 Q3 Q4
Decode Read
register ‘f’
Process 
Data
No 
operation
If skip:
Q1 Q2 Q3 Q4
No 
operation
No 
operation
No 
operation
No 
operation
If skip and followed by 2-word instruction:
Q1 Q2 Q3 Q4
No 
operation
No 
operation
No 
operation
No 
operation
No 
operation
No 
operation
No 
operation
No 
operation
Example:
HERE
FALSE
TRUE
BTFSS
:
:
FLAG, 1, 0
Before Instruction
PC = address (HERE)
After Instruction
If FLAG<1> =  0;
PC = address (FALSE)
If FLAG<1> =  1;
PC = address (TRUE)