PIC16(L)F1824/8
DS40001419F-page 272 2010-2015 Microchip Technology Inc.
FIGURE 25-32: BUS COLLISION TIMING FOR TRANSMIT AND ACKNOWLEDGE
25.6.13.1 Bus Collision During a Start
Condition
During a Start condition, a bus collision occurs if:
a) SDA or SCL are sampled low at the beginning of
the Start condition (Figure 25-33).
b) SCL is sampled low before SDA is asserted low
(Figure 25-34).
During a Start condition, both the SDA and the SCL
pins are monitored.
If the SDA pin is already low, or the SCL pin is already
low, then all of the following occur:
the Start condition is aborted,
the BCL1IF flag is set and
the MSSP1 module is reset to its Idle state
(Figure 25-33).
The Start condition begins with the SDA and SCL pins
deasserted. When the SDA pin is sampled high, the
Baud Rate Generator is loaded and counts down. If the
SCL pin is sampled low while SDA is high, a bus colli-
sion occurs because it is assumed that another master
is attempting to drive a data ‘1’ during the Start
condition.
If the SDA pin is sampled low during this count, the
BRG is reset and the SDA line is asserted early
(Figure 25-35). If, however, a ‘1’ is sampled on the SDA
pin, the SDA pin is asserted low at the end of the BRG
count. The Baud Rate Generator is then reloaded and
counts down to zero; if the SCL pin is sampled as0
during this time, a bus collision does not occur. At the
end of the BRG count, the SCL pin is asserted low.
SDA
SCL
BCL1IF
SDA released
SDA line pulled low
by another source
Sample SDA. While SCL is high,
data does not match what is driven
Bus collision has occurred.
Set bus collision
interrupt (BCL1IF)
by the master.
by master
Data changes
while SCL = 0
Note: The reason that bus collision is not a
factor during a Start condition is that no
two bus masters can assert a Start condi-
tion at the exact same time. Therefore,
one master will always assert SDA before
the other. This condition does not cause a
bus collision because the two masters
must be allowed to arbitrate the first
address following the Start condition. If the
address is the same, arbitration must be
allowed to continue into the data portion,
Repeated Start or Stop conditions.