Datasheet

Micrel, Inc. MIC20xx Family
August 2011
13
M9999-080211-D
AC Electrical Characteristics
Symbol Parameter Condition Min. Typ. Max. Units
t
RISE
Output Turn-on rise time
R
L
= 10, C
LOAD
= 1µF,
V
OUT
= 10% to 90%
C
SLEW
(7)
= Open
500 1000 1500 µs
Delay before asserting or releasing
FAULT/
MIC2003 – MIC2009
MIC2009A, MIC2005A
Time from current limiting to FAULT/ state
change
20
32
49
t
D_FAULT
Delay before asserting or releasing
FAULT/
MIC2013 – MIC2019
MIC2019A
Time from I
OUT
continuously exceeding
primary current limit condition to FAULT/
state change
77
128
192
ms
t
D_LIMIT
Delay before current limiting
MIC2013 – MIC2019
MIC2019A
77
128
192
ms
t
RESET
Delay before resetting Kickstart™
current limit delay, t
D
_
LIMIT
MIC2013 – MIC2019
MIC2019A
Out of current limit following a current limit
event.
77
128
192
ms
t
ON_DLY
Output Turn-on Delay
R
L
= 43, C
L
= 120µF,
V
EN
= 50% to V
OUT
= 10%
*C
SLEW
= Open
1000 1500 µs
t
OFF_DLY
Output Turn-off Delay
R
L
= 43, C
L
= 120µF,
V
EN
= 50% to V
OUT
= 90%
*C
SLEW
= Open
700 µs
ESD
(8)
Symbol Parameter Condition Min. Typ. Max. Units
V
OUT
and GND ±4
V
ESD_HB
Electro Static Discharge Voltage:
Human Body Model
All other pins ±2
kV
V
ESD_MCHN
Electro Static Discharge Voltage;
Machine Model
All pins
Machine Model
±200
V
Notes:
7. Whenever C
SLEW
is present.
8. Devices are ESD sensitive. Handling precautions recommended. Human body model, 1.5k in series with 100pF.