© 2011 Microchip Technology Inc. DS25095A-page 29
MCP9808
5.1.6 RESOLUTION REGISTER
This register allows the user to change the sensor
resolution (see Section 5.2.4 “Temperature
Resolution”). The POR default resolution is
+0.0625°C. The selected resolution is also reflected in
the Capability register (see Register 5-2).
FIGURE 5-8: Timing Diagram for Changing T
A
Resolution to +0.0625°C <0000 0011>b (see
Section 4.0 “Serial Communication”).
REGISTER 5-7: RESOLUTION REGISTER ( ADDRESS ‘0000 1000’b)
U-0 U-0 U-0 U-0 U-0 U-0 R/W-1 R/W-1
Resolution
bit 7 bit 0
Legend:
R = Readable bit W = Writable bit U = Unimplemented bit, read as ‘0
-n = Value at POR ‘1’ = Bit is set ‘0’ = Bit is cleared x = Bit is unknown
bit 7-2 Unimplemented: Read as ‘0
bit 1-0 Resolution bits
00 = +0.5°C (t
CONV
= 30 ms typical)
01 = +0.25°C (t
CONV
= 65 ms typical)
10 = +0.125°C (t
CONV
= 130 ms typical)
11 = +0.0625°C (power-up default, t
CONV
= 250 ms typical)
SDA
A
C
K
0011
A
A
C
K
S
2
A
1
A
0
12345678 12345678
SCL
Address Byte
W
MCP9808 MCP9808
A
C
K
P
12345678
DataResolution Pointer
MCP9808
00001
000 00000
011