Datasheet

2012 Microchip Technology Inc. DS25160A-page 23
MCP1755/1755S
5.5 Pulsed Load Applications
For some applications, there are pulsed load current
events that may exceed the specified 300 mA
maximum specification of the MCP1755/1755S. The
internal current limit of the MCP1755/1755S will
prevent high peak load demands from causing non-
recoverable damage. The 300 mA rating is a maximum
average continuous rating. As long as the average
current does not exceed 300 mA, higher pulsed load
currents can be applied to the MCP1755/1755S
. The
typical foldback current limit for the MCP1755/1755S is
350 mA (T
A
=+25°C).