Datasheet

Micrel, Inc. KS8999
January 2005
46
KS8999
Figure 17. KS8999 MAC Mode TimingData Sent from KS8999 MAC mode to External PHY Device
Figure 18. KS8999 MAC Mode Transit Timing
Symbol Parameter Min Typ Max Units
t
CYC
Clock Cycle (100BaseT) 40 ns
t
CYC
Clock Cycle (10BaseT) 400 ns
t
OV
Output Valid 7 11 16 ns
Table 12. KS8999 MAC Mode Transmit Timing Parameters