2017 Microchip Technology Inc. DS00002348A-page 17
KSZ8873MLL/FLL/RLL
2. Start cable diagnostic test by writing a ‘1’ to register 42, bit [4]. This enable bit is self-clearing.
3. Wait (poll) for register 42, bit [4] to return a ‘0’, indicating cable diagnostic test is complete.
4. Read cable diagnostic test results in register 42, bits [6:5]. The results are as follows:
00 = normal condition (valid test)
01 = open condition detected in cable (valid test)
10 = short condition detected in cable (valid test)
11 = cable diagnostic test failed (invalid test)
The ‘11’ case, invalid test, occurs when the KSZ8873MLL/FLL/RLL is unable to shut down the link partner. In this
instance, the test is not run, because it would be impossible for the KSZ8873MLL/FLL/RLL to determine if the detected
signal is a reflection of the signal generated or a signal from another source.
5. Get distance to fault by concatenating register 42, bit [0] and register 43, bits [7:0]; and multiplying the result by
a constant of 0.4. The distance to the cable fault can be determined by the following formula:
EQUATION 3-1:
Concatenated values of registers 42 and 43 are converted to decimal before multiplying by 0.4.
The constant (0.4) may be calibrated for different cabling conditions, including cables with a velocity of propagation that
varies significantly from the norm.
3.2 Power Management
The KSZ8873MLL/FLL/RLL supports enhanced power management features in low power state with energy detection
to ensure low-power dissipation during device idle periods. There are five operation modes under the power manage-
ment function, which is controlled by two bits in Register 195 (0xC3) and one bit in Register 29 (0x1D), 45 (0x2D) as
shown below:
Register 195 bit[1:0] = 00 Normal Operation Mode
Register 195 bit[1:0] = 01 Energy Detect Mode
Register 195 bit[1:0] = 10 Soft Power Down Mode
Register 195 bit[1:0] = 11 Power Saving Mode
Register 29, 45 bit 3 = 1 Port Based Power Down Mode
Table 3-3 indicates all internal function blocks status under four different power management operation modes.
3.2.1 NORMAL OPERATION MODE
This is the default setting bit[1:0]=00 in register 195 after the chip power-up or hardware reset. When KSZ8873MLL/
FLL/RLL is in this normal operation mode, all PLL clocks are running, PHY and MAC are on, and the host interface is
ready for CPU read or write.
TABLE 3-3: INTERNAL FUNCTION BLOCK STATUS
KSZ8873MLL/FLL/RLL
Function Blocks
Power Management Operation Modes
Normal Mode
Power Saving
Mode
Energy Detect
Mode
Soft Power Down
Mode
Internal PLL Clock Enabled Enabled Disabled Disabled
Tx/Rx PHY Enabled
Rx unused block
disabled
Energy detect at Rx Disabled
MAC Enabled Enabled Disabled Disabled
Host Interface Enabled Enabled Disabled Disabled
DDis cetan
·
to cable fault in meters0.4 Register 26 bit [0] Register 27 bits [7:0]=