FIGURE 3-3: AUTO-NEGOTIATION AND PARALLEL OPERATION
3.1.12 LINKMD
®
CABLE DIAGNOSTICS
KSZ8873MLL/FLL/RLL supports LinkMD. The LinkMD feature utilizes time domain reflectometry (TDR) to analyze the
cabling plant for common cabling problems such as open circuits, short circuits, and impedance mismatches.
LinkMD works by sending a pulse of known amplitude and duration down the MDI and MDI-X pairs and then analyzes
the shape of the reflected signal. Timing the pulse duration gives an indication of the distance to the cabling fault. Inter-
nal circuitry displays the TDR information in a user-readable digital format.
Cable diagnostics are only valid for copper connections and do not support fiber optic operation.
3.1.12.1 Access
LinkMD is initiated by accessing the PHY special control/status registers {26, 42} and the LinkMD result registers {27,
43} for ports 1 and 2 respectively; and in conjunction with the port registers control 13 for ports 1 and 2 respectively to
disable Auto MDI/MDIX.
Alternatively, the MIIM PHY registers 0 and 29 can be used for LinkMD access.
3.1.12.2 Usage
The following is a sample procedure for using LinkMD with registers {42,43,45} on port 2.
1. Disable auto MDI/MDI-X by writing a ‘1’ to register 45, bit [2] to enable manual control over the differential pair
used to transmit the LinkMD pulse.
START AUTO-NEGOTIATION
FORCE LINK SETTING
LISTEN FOR 10BASE-T
LINK PULSES
LISTEN FOR 100BASE-TX
IDLES
ATTEMPT AUTO-
NEGOTIATION
LINK MODE SET
BYPASS AUTO-NEGOTIATION
AND SET LINK MODE
LINK MODE SET?
PARALLEL
OPERATION
NO
YES
YES
NO
JOIN FLOW