9.0 SELECTION OF ISOLATION TRANSFORMERS
A 1:1 isolation transformer is required at the line interface. Use one with integrated common-mode chokes for designs
exceeding FCC requirements.
Table 9-1 lists recommended transformer characteristics.
TABLE 9-1: TRANSFORMER SELECTION CRITERIA
Parameter Value Test Conditions
Turns Ratio 1 CT : 1 CT —
Open-Circuit Inductance (min.) 350 µH 100 mV, 100 kHz, 8 mA
Leakage Inductance (max.) 0.4 µH 1 MHz (min.)
Interwinding Capacitance (max.) 12 pF —
D.C. Resistance (max.) 0.9 —
Insertion Loss (max.) –1.0 dB 0 MHz to 65 MHz
HIPOT (min.) 1500 V
RMS
—
TABLE 9-2: QUALIFIED SINGLE-PORT MAGNETICS
Manufacturer Part Number Auto MDI-X
Bel Fuse S558-5999-U7 Yes
Bel Fuse (MagJack) SI-46001 Yes
Bel Fuse (MagJack) SI-50170 Yes
Delta LF8505 Yes
LanKom LF-H41S Yes
Pulse H1102 Yes
Pulse (Low Cost) H1260 Yes
Datatronic NT79075 Yes
Transpower HB726 Yes
YCL LF-H41S Yes
TDK (MagJack) TLA-6T718 Yes
TABLE 9-3: TYPICAL REFERENCE CRYSTAL CHARACTERISTICS
Characteristic Value
Frequency 25.00000 MHz
Frequency Tolerance (max.) ±50 ppm
Load Capacitance (max.) 20 pF
Series Resistance 40