Datasheet
KSZ8081MNX/RNB
DS00002202C-page 42 2016-2018 Microchip Technology Inc.
18.5:0 Reserved Reserved RO 00_0001
Register 1Bh – Interrupt Control/Status
1B.15
Jabber
Interrupt
Enable
1 = Enable jabber interrupt
0 = Disable jabber interrupt
RW 0
1B.14
Receive Error
Interrupt
Enable
1 = Enable receive error interrupt
0 = Disable receive error interrupt
RW 0
1B.13
Page
Received
Interrupt
Enable
1 = Enable page received interrupt
0 = Disable page received interrupt
RW 0
1B.12
Parallel Detect
Fault Interrupt
Enable
1 = Enable parallel detect fault inter-
rupt
0 = Disable parallel detect fault inter-
rupt
RW 0
1B.11
Link Partner
Acknowledge
Interrupt
Enable
1 = Enable link partner acknowledge
interrupt
0 = Disable link partner acknowledge
interrupt
RW 0
1B.10
Link-Down
Interrupt
Enable
1= Enable link-down interrupt
0 = Disable link-down interrupt
RW 0
1B.9
Remote Fault
Interrupt
Enable
1 = Enable remote fault interrupt
0 = Disable remote fault interrupt
RW 0
1B.8
Link-Up
Interrupt
Enable
1 = Enable link-up interrupt
0 = Disable link-up interrupt
RW 0
1B.7
Jabber
Interrupt
1 = Jabber occurred
0 = Jabber did not occur
RO/SC 0
1B.6
Receive Error
Interrupt
1 = Receive error occurred
0 = Receive error did not occur
RO/SC 0
1B.5
Page Receive
Interrupt
1 = Page receive occurred
0 = Page receive did not occur
RO/SC 0
1B.4
Parallel Detect
Fault Interrupt
1 = Parallel detect fault occurred
0 = Parallel detect fault did not occur
RO/SC 0
1B.3
Link Partner
Acknowledge
Interrupt
1 = Link partner acknowledge
occurred
0 = Link partner acknowledge did not
occur
RO/SC 0
1B.2
Link-Down
Interrupt
1 = Link-down occurred
0 = Link-down did not occur
RO/SC 0
1B.1
Remote Fault
Interrupt
1 = Remote fault occurred
0 = Remote fault did not occur
RO/SC 0
1B.0
Link-Up
Interrupt
1 = Link-up occurred
0 = Link-up did not occur
RO/SC 0
TABLE 4-2: REGISTER DESCRIPTION (CONTINUED)
Address Name Description Mode Default