2017 Microchip Technology Inc. DS00002436B-page 21
KSZ8041TL/FTL/MLL
FIGURE 3-1: AUTO-NEGOTIATION FLOW CHART
3.9 MII Management (MIIM) Interface
The KSZ8041TL/FTL/MLL supports the IEEE 802.3 MII Management Interface, also known as the Management Data
Input/Output (MDIO) Interface. This interface allows upper-layer devices to monitor and control the state of the
KSZ8041TL/FTL/MLL. An external device with MIIM capability is used to read the PHY status and/or configure the PHY
settings. Further details on the MIIM interface can be found in Clause 22.2.4 of the IEEE 802.3 Specification.
The MIIM interface consists of the following:
A physical connection that incorporates the clock line (MDC) and the data line (MDIO).
A specific protocol that operates across the aforementioned physical connection that allows a external controller
to communicate with one or more PHY devices. Each KSZ8041TL/FTL/MLL device is assigned a unique PHY
address between 1 and 7 by its PHYAD[2:0] strapping pins. Also, every KSZ8041TL/FTL/MLL device supports the
broadcast PHY address 0, as defined per the IEEE 802.3 Specification, which can be used to read/write to a sin-
gle KSZ8041TL/FTL/MLL device, or write to multiple KSZ8041TL/FTL/MLL devices simultaneously.
A set of 16-bit MDIO registers. Register [0:6] are required, and their functions are defined per the IEEE 802.3
Specification. The additional registers are provided for expanded functionality.
The following table shows the MII Management frame format for the KSZ8041TL/FTL/MLL.
START AUTO-NEGOTIATION
FORCE LINK SETTING
LISTEN FOR 10BASE-T
LINK PULSES
LISTEN FOR 100BASE-TX
IDLES
ATTEMPT AUTO-
NEGOTIATION
LINK MODE SET
BYPASS AUTO-NEGOTIATION
AND SET LINK MODE
LINK MODE SET?
PARALLEL
OPERATION
NO
YES
YES
NO
JOIN FLOW