9.6 COMMUNICATIONS: BASIC OPERATIONS
The USART Asynchronous Operations window can be opened by selecting:
Communications: Basic Operations
from the tool bar, or
B
asic Operations from the menu bar
The USART Synchronous Master Basic Operations window is shown in Figure 9-3.
There are two basic communications commands, Read and Write.
Data can be transmitted to the target device as 7-bit ASCII or 8-bit byte. 7-bit ASCII
data is entered in the left-hand window. 8-bit byte is entered in the right-hand column.
Both transmitted and received data is displayed in the Transaction window.
The command will be logged in the Transactions window. A listing of the command
abbreviations is given in Table 9-2.
FIGURE 9-3: USART SYNCHRONOUS MASTER BASIC OPERATIONS
9.7 SCRIPT BUILDER
USART Asynchronous commands can be combined into scripts, saved, and used over
again. The Script Builder window is opened by selecting Communications > Script >
Script Builder from the menu bar. The Script Builder is shown in Figure 9-4.
The Script Builder window is divided into four columns as shown in Figures 9-5 through
9-8.
Note: The “x” indicates the value is a hexadecimal number. Clicking on “x” will
toggle it to a “d” indicating that the value is a decimal number.