Datasheet

Table Of Contents
PICkit™ Serial Analyzer User’s Guide
DS51647C-page 48 © 2009 Microchip Technology Inc.
6.5 CONFIGURING LIN SLAVE COMMUNICATIONS MODE
Once the communications mode has been selected, it is configured from the
Configuration Wizard or menu bar.
Configuration Wizard – Select PICkit Serial Analyzer > Run Configuration Wizard
from the menu bar
Menu Bar – Select PICkit Serial Analyzer > Configure Communications Mode
The Configure Mode window will open. Depending on the view selected, the Basic
View (Figure 6-1) displays a minimum choice of configurations commands. The
Advanced View (Figure 6-2) displays an extended choice of configuration commands.
Save the configuration by clicking on the Save Changes button.
FIGURE 6-1: LIN CONFIGURE COMMUNICATIONS MODE – BASIC VIEW
OPTIONS
Enable Event Markers – Enable event markers
Enable Time Markers – Enable time-stamp to accompany all event markers
LIN BAUD
Enter desired baud rate here. You are limited to a range of 1000 to 20000.
SCRIPT TIME-OUT
When transmitting frames, the software will wait a maximum of script time-out ms to
receive a script complete tag before issuing an error. If your LIN hardware is slow to
respond, you may need to increase the script time-out to avoid errors.