Datasheet

2013-2014 Microchip Technology Inc. DS70000689D-page 497
dsPIC33EPXXXGM3XX/6XX/7XX
TABLE 33-60: ADCx CONVERSION (10-BIT MODE) TIMING REQUIREMENTS
AC CHARACTERISTICS
Standard Operating Conditions (see Note 1): 3.0V to 3.6V
(unless otherwise stated)
Operating temperature -40°C T
A +85°C for Industrial
-40°C T
A +125°C for Extended
Param
No.
Symbol Characteristic Min. Typ.
(4)
Max. Units Conditions
Clock Parameters
AD50 T
AD ADCx Clock Period 75 ns
AD51 tRC ADCx Internal RC Oscillator Period 250 ns
Conversion Rate
AD55 t
CONV Conversion Time 12 TAD ——
AD56 FCNV Throughput Rate 1.1 Msps Using simultaneous
sampling
AD57a T
SAMP Sample Time When Sampling Any
ANx Input
2 TAD ——
AD57b T
SAMP Sample Time When Sampling the
Op Amp Outputs
4 TAD ——
Timing Parameters
AD60 t
PCS Conversion Start from Sample
Trigger
(2)
2 TAD —3 TAD Auto-convert trigger not
selected
AD61 t
PSS Sample Start from Setting
Sample (SAMP) bit
(2)
2 TAD —3 TAD
AD62 t
CSS Conversion Completion to
Sample Start (ASAM = 1)
(2)
—0.5 TAD ——
AD63 t
DPU Time to Stabilize Analog Stage
from ADC Off to ADC On
(2)
——20s (Note 3)
Note 1: Device is functional at V
BORMIN < VDD < VDDMIN, but will have degraded performance. Device functionality
is tested, but not characterized. Analog modules: ADC, op amp/comparator and comparator voltage
reference, will have degraded performance. Refer to Parameter BO10 in Table 33-12 for the minimum and
maximum BOR values.
2: Because the sample caps will eventually lose charge, clock rates below 10 kHz may affect linearity
performance, especially at elevated temperatures.
3: The parameter, t
DPU, is the time required for the ADCx module to stabilize at the appropriate level when
the module is turned on (AD1CON1<ADON> = 1). During this time, the ADCx result is indeterminate.
4: These parameters are characterized, but not tested in manufacturing.