Datasheet
2013-2014 Microchip Technology Inc. DS70000689D-page 221
dsPIC33EPXXXGM3XX/6XX/7XX
REGISTER 14-2: ICxCON2: INPUT CAPTURE x CONTROL REGISTER 2
U-0 U-0 U-0 U-0 U-0 U-0 U-0 R/W-0
— — — — — — —IC32
(1)
bit 15 bit 8
R/W-0 R/W/HS-0 U-0 R/W-0 R/W-1 R/W-1 R/W-0 R/W-1
ICTRIG
(2)
TRIGSTAT
(3)
—SYNCSEL4
(4)
SYNCSEL3
(4)
SYNCSEL2
(4)
SYNCSEL1
(4)
SYNCSEL0
(4)
bit 7 bit 0
Legend: HS = Hardware Settable
bit
R = Readable bit W = Writable bit U = Unimplemented bit, read as ‘0’
-n = Value at POR ‘1’ = Bit is set ‘0’ = Bit is cleared x = Bit is unknown
bit 15-9 Unimplemented: Read as ‘0’
bit 8 IC32: Input Capture x 32-Bit Timer Mode Select bit (Cascade mode)
(1)
1 = Odd ICx and Even ICx form a single 32-bit input capture module
0 = Cascade module operation is disabled
bit 7 ICTRIG: Input Capture x Trigger Operation Select bit
(2)
1 = Input source is used to trigger the input capture timer (Trigger mode)
0 = Input source is used to synchronize the input capture timer to the timer of another module
(Synchronization mode)
bit 6 TRIGSTAT: Timer Trigger Status bit
(3)
1 = ICxTMR has been triggered and is running
0 = ICxTMR has not been triggered and is being held clear
bit 5 Unimplemented: Read as ‘0’
Note 1: The IC32 bit in both the Odd and Even ICx must be set to enable Cascade mode.
2: The input source is selected by the SYNCSEL<4:0> bits of the ICxCON2 register.
3: This bit is set by the selected input source (selected by SYNCSEL<4:0> bits); it can be read, set and
cleared in software.
4: Do not use the ICx module as its own Sync or Trigger source.
5: This option should only be selected as a trigger source and not as a synchronization source.
6: Each Input Capture x module (ICx) has one PTG input source. See Section 25.0 “Peripheral Trigger
Generator (PTG) Module” for more information.
PTGO8 = IC1, IC5
PTGO9 = IC2, IC6
PTGO10 = IC3, IC7
PTGO11 = IC4, IC8