Datasheet
2018 Microchip Technology Inc. Data Sheet Complete DS40002059A-page 53
ATxmega32E5/16E5/8E5
25. IRCOM – IR Communication Module
25.1 Features
Pulse modulation/demodulation for infrared communication
IrDA compatible for baud rates up to 115.2Kbps
Selectable pulse modulation scheme
3/16 of the baud rate period
Fixed pulse period, 8-bit programmable
Pulse modulation disabled
Built-in filtering
Can be connected to and used by any USART
25.2 Overview
AVR XMEGA devices contain an infrared communication module (IRCOM) that is IrDA compatible for baud rates up to
115.2Kbps. It can be connected to any USART to enable infrared pulse encoding/decoding for that USART.