Datasheet
50.6.14 Synchronization with PWM
The inputs TIOAx/TIOBx can be bypassed, and thus channel trigger/capture events can be directly driven by the
independent PWM module.
PWM comparator outputs (internal signals without dead-time insertion - OCx), respectively source of the PWMH/
L[2:0] outputs, are routed to the internal TC inputs. These specific TC inputs are multiplexed with TIOA/B input signal
to drive the internal trigger/capture events.
The selection is made in the Extended Mode register (TC_EMR) fields TRIGSRCA and TRIGSRCB (see “TC
Extended Mode Register”).
Each channel of the TC module can be synchronized by a dif
ferent PWM channel as described in the following figure.
Figure 50-16. Synchronization with PWM
Timer Counter
Channel 0
TC_EMR0.TRIGSRCA
TIOA0
TIOA0
TC_EMR0.TRIGSRCB
TIOB0
TIOB0
Timer Counter
Channel 1
TC_EMR1.TRIGSRCA
TIOA1
TIOA1
TC_EMR1.TRIGSRCB
TIOB1
TIOB1
Timer Counter
Channel 2
TC_EMR2.TRIGSRCA
TIOA2
TIOA2
TC_EMR2.TRIGSRCB
TIOB2
TIOB2
PWM comparator outputs (internal signals)
respectively source of PWMH/L[2:0]
Timer Counter
1
1
1
1
1
1
SAM E70/S70/V70/V71 Family
T
imer Counter (TC)
© 2019 Microchip T
echnology Inc.
Datasheet