Datasheet
...........continued
Value Name Description
0x2 CAPTMIN On rising edge of a valid recoverable Fault n, capture counter value on channel
selected by CHSEL[1:0], if COUNT value is lower than the last stored capture value
(CC).
INTFLAG.FAULTn flag rises on each local minimum detection.
0x3 CAPTMAX On rising edge of a valid recoverable Fault n, capture counter value on channel
selected by CHSEL[1:0], if COUNT value is higher than the last stored capture value
(CC).
INTFLAG.FAULTn flag rises on each local maximun detection.
0x4 LOCMIN On rising edge of a valid recoverable Fault n, capture counter value on channel
selected by CHSEL[1:0].
INTFLAG.FAULTn flag rises on each local minimum value detection.
0x5 LOCMAX On rising edge of a valid recoverable Fault n, capture counter value on channel
selected by CHSEL[1:0].
INTFLAG.FAULTn flag rises on each local maximun detection.
0x6 DERIV0 On rising edge of a valid recoverable Fault n, capture counter value on channel
selected by CHSEL[1:0].
INTFLAG.FAULTn flag rises on each local maximun or minimum detection.
Bits 11:10 – CHSEL[1:0] Recoverable Fault n Capture Channel
These bits select the channel for capture operation triggered by recoverable Fault n.
Value Name Description
0x0
CC0 Capture value stored into CC0
0x1
CC1 Capture value stored into CC1
0x2
CC2 Capture value stored into CC2
0x3
CC3 Capture value stored into CC3
Bits 9:8 – HALT[1:0] Recoverable Fault n Halt Operation
These bits select the halt action for recoverable Fault n.
Value Name Description
0x0
DISABLE Halt action disabled
0x1
HW Hardware halt action
0x2
SW Software halt action
0x3
NR Non-recoverable fault
Bit 7 – RESTART Recoverable Fault n Restart
Setting this bit enables restart action for Fault n.
SAM D21 Family
TCC – Timer/Counter for Control Applications
© 2018 Microchip Technology Inc.
Datasheet Complete