Datasheet
This bit is not write-synchronized.
Value Description
0
Automatic acknowledge is disabled.
1
Automatic acknowledge is enabled.
Bit 9 – GCMD PMBus Group Command
This bit enables PMBus group command support. When enabled, the Stop Recived interrupt flag
(INTFLAG.PREC) will be set when a STOP condition is detected if the slave has been addressed since
the last STOP condition on the bus.
This bit is not write-synchronized.
Value Description
0
Group command is disabled.
1
Group command is enabled.
Bit 8 – SMEN Smart Mode Enable
When smart mode is enabled, data is acknowledged automatically when DATA.DATA is read.
This bit is not write-synchronized.
Value Description
0
Smart mode is disabled.
1
Smart mode is enabled.
Related Links
25. SERCOM – Serial Communication Interface
SAM D21 Family
SERCOM I2C – Inter-Integrated Circuit
© 2018 Microchip Technology Inc.
Datasheet Complete