Datasheet

BOD33: Brown-Out Detector on VDDANA
BOD12: Voltage Regulator Internal Brown-Out Detector on VDDCORE. The Voltage Regulator
Internal BOD is calibrated in production and its calibration configuration is stored in the NVM User
Row. This configuration should not be changed if the user row is written to assure the correct
behavior of the BOD12.
8.4.1 Power-On Reset on VDDANA
POR monitors VDDANA. It is always activated and monitors voltage at startup and also during all the
sleep modes. If VDDANA goes below the threshold voltage, the entire chip is reset.
8.4.2 Brown-Out Detector on VDDANA
BOD33 monitors VDDANA. Refer to SYSCTRL – System Controller for details.
Related Links
17. SYSCTRL – System Controller
8.4.3 Brown-Out Detector on VDDCORE
Once the device has started up, BOD12 monitors the internal VDDCORE.
SAM D21 Family
Power Supply and Start-Up Considerations
© 2018 Microchip Technology Inc.